30 kVA / 35kVA / 40 kVA / 45kVA


PARAMETERS DG MODELS
Duty (Standby/ Prime) Prime Stand By Stand By Prime Stand By
50 HZ PRIME Rating(kVA) 30 kVA 30 kVA 35 kVA 40 kVA 45 kVA
Rated(kWe) 24 24 35 32 36
Engine Model 3445TCIGM-C2 3385 ELSTCGMC2 3445 TCIGM-C2 4575 TCIGM-C2 4575TCIGM-C2
No of Phases 1/3 1/3 1/3 1/3 1/3
No of Cylinders 3 3 3 4 4
Output Voltage (V) 230V/415V 230V/415V 230V/415V 230V/415V 230V/415V
Current (A) (1Phase / 3Phase) 130.4/ 41.7 130.4/ 41.7 152.2 / 48.7 173.9 / 55.7 195.7/62.6
Power Factor (lagging) 0.8 0.8 0.8 0.8 0.8
Frequency (Hz)/ RPM 50/1500 50/1500 50/1500 50/1500 50/1500
Governing class A1 A1 A1 A1 G2
Starting system 12 V DC Elec 12 V DC Elec 12 V DC Elec 12 V DC Elec 12 V DC Elec
Fuel Tank Capacity (lits) 115 115 115 115 115
Genset Dimension (LxWxH $$) (mm) Approx. 3 Phase :- 2000 X 980 X 1280
1 Phase :- 2200 X 980 X 1280
3 Phase :- 2000 X 980 X 1280
1 Phase :- 2200 X 980 X 1280
3 Phase :- 2000 X 980 X 1280
1 Phase :- 2200 X 980 X 1280
3 Phase :- 2000 X 980 X 1280
1 Phase :- 2200 X 980 X 1280
3 Phase :- 2000 X 980 X 1280
1 Phase :- 2200 X 980 X 1280
Genset Weight (Kg), Appx 3 Phase :- 935 1 Phase :- 1026 3 Phase :- 935 1 Phase :- 1026 3 Phase :- 926 1 Phase :- 984 3 Phase :- 985 1 Phase :- 1051 3 Phase :- 996 1 Phase :- 1120
Make Mahindra Mahindra Mahindra Mahindra Mahindra
Power Output# (HP) 44 38.6 44 57 57
Aspiration Turbocharged & Intercooled Turbocharged Turbocharged & Intercooled Turbocharged & Intercooled Turbocharged & Intercooled
No of Cylinders 3 3 3 4 4
Bore x Stroke (mm) 88.9 X 110 88.9 X 120 88.9 X 110 88.9 X 110 88.9 X 110
Displacement (cc) 2048 2235 2048 2731 2731
Fuel consumption @ 75% load (lit/hr) ^ 5.7 - - 7.3 -
Fuel consumption @ 100% load (lit/hr) ^ 7.3 - - 9.9 -
Lube oil specification SAE15W40 CI4 SAE15W40 CI4 SAE15W40 CI4 SAE15W40 CI4 SAE15W40 CI4
Total Lube Oil capacity (lit) 7 7 7 10.5 10.5
Lube Oil Consumtion (lit/hr) $ 0.15% of Fuel Consumption 0.15% of Fuel Consumption 0.15% of Fuel Consumption 0.15% of Fuel Consumption 0.15% of Fuel Consumption
Lube oil change period (hrs.) 300 hrs. for Oil Top Up
600 hrs. for Oil change
300 hrs. for Oil Top Up
600 hrs. for Oil change
300 hrs. for Oil Top Up
600 hrs. for Oil change
300 hrs. for Oil Top Up
600 hrs. for Oil change
300 hrs. for Oil Top Up
600 hrs. for Oil change
Radiator coolant capacity (liter) 9.5 9.5 9.5 9.5 9.5
Alternator
Enclosure Type CG/LS
Enclosure Type IP23
Voltage regulation ±1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%

 

All Specifications are at Standard NTP operating conditions

  • Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
  • Engine Power at 110 % load
  • Fuel -High Speed diesel (HSD IS 1460:2005)
  • Represent the Standby Ratings
  • Considering 0.89 Specific Gravity of Oil
  • Engine Power will have ± 5 % Tolerance
  • For CG only 3 Phase Configuration available
  • Height Without Silencer